Designed specifically for 12G-SDI, and fixed installation
Copper foil and high-density tinned copper braided shielding
Highly foamed multi-layer PE insulation
Flame resistance Riser rated (CMR)
SUPER COAX
L-CHD/L-CHLT SERIES
L-4.5CHD
Model Number
Nom. O.D (mm)
Weight (kg/100m)
AWG
Inner cond. O.D (mm)
Insulation O.D (mm)
Outer Conductors – Braid comp. (mm/ends/carriers)
Inner cond. resist. (Ω/km)
Attenuation (dB/100m – 1.5 GHz)
L-2.5CHD
4.2
2.6
23
0.59
2.59
16.9
66.9
43.1
L-2.5CHLT
4.2
1.8
23
0.59
2.59
21.5
66.9
43.1
L-4.5CHD-PL
7.0
6.2
18
1.02
4.57
9.9
23.3
25.1
L-4.5CHD
7.0
6.2
18
1.02
4.57
9.9
23.3
25.1
L-4CHD
6.1
5.2
20
0.82
3.68
11.4
36.4
30.6
L-5CHD
7.7
7.4
17
1.20
4.9
8.2
16.1
22.5
L-6CHD
8.9
9.0
16
1.40
6.1
7.7
11.8
19.0
L-7CHD
10.2
13.0
14
1.80
7.3
6.1
7.1
15.9
L-8CHD
11.1
13.5
12
2.00
8.2
6.3
5.8
14.1
Key Features – L-CHD
HD-Serial Digital Video.
Satellite Head Ends.
HDTV Upgrades.
Broadband Facilities.
SMPTE 259M, 292M,424M.
Best suited to 3G-SDI / HD-SDI transmission
Highly-foamed PE insulation allows further improvement in the attenuation characteristics.
Multi-layer insulation in which to each layer is given a different foaming ratio is used to increase strength.
Tinned copper braid with aluminum foil brings excellent shielding.
L-2.5CHD is ideal for internal rack wiring.
Flame resistance UL 1666 Riser (L-2.5CHD, L-4CHD, L-4.5CHD, and L-5CHD).
Key Features – L-CHLT
Lightweight type with copper-coated aluminum braid shield.
Approximately 30% lighter than that of L-2.5CHD, ideal for relay cars and trucks.
The way to connect the copper-coated aluminum braid is the same with copper braid
Due to the nature of the copper-clad aluminum wire,
Able to use Cable stripper.
Canare’s variety of 75 ohm coaxial cables support full-range of video formats. Our cutting-edge Supper Low Loss Coax and Low Loss Coax are ideal for 3G-SDI / HD-SDI distribution.
STANDARD COAX
SOLID PE INSULATION
L-3C2VS
Model Number
Nom. O.D (mm)
Weight (kg/100m)
AWG
Inner cond. O.D (mm)
Insulation O.D (mm)
Outer Conductors – Braid comp. (mm/ends/carriers)
Inner cond. resist. (Ω/100m)
Static capacity (pF/m)
Attenuation (dB/100m – 10 MHz)
LV-61S
6.1
5.0
24
0.60
3.6
0.12A / 6 / 24 (93%)
8.5
67
3.8
LV-77S
7.7
9.0
22
0.78
4.8
0.12A / 7 24 (92%), 0.12A / 8 / 24 (95%)
5.0
67
3.4
L-5C2VS
7.4
6.8
22
0.78
4.8
0.12A / 7 / 24 (93%)
5.0
67
2.9
L-3C2VS
5.5
4.5
25
0.54
3.1
0.12A / 7 / 16 (94%)
10.5
67
4.5
L-1.5C2VS
2.9
1.3
31
0.27
1.6
0.10A / 5 / 16 (94%)
41.9
69
8.7
Key Features:
Ideal for locations requiring cable bending
Flexible stranded center conductor
High-density braided shield
Dielectric strips away clean from conductor
LV-61S is equivalent to RG-59B/U
Stays flexible in sub-zero weather
Note: Cable strippers (TS100 series) cannot be used for L-1.5C2VS and LV-77S